Commit b769f920 authored by Owen W. Taylor's avatar Owen W. Taylor
Browse files

Don't add together voltage_now values for multiple batteries

If there are multiple batteries, it's not possible to compute an
overall "voltage_now" for the system, so just ignore it.

https://bugzilla.gnome.org/show_bug.cgi?id=747370
parent 3eb42d2c
......@@ -148,6 +148,7 @@ battery_poll(Battery *battery)
battery->charge_full = -1.0;
battery->charge_full_design = -1.0;
battery->capacity_now = -1.0;
battery->voltage_now = -1.0;
get_file_contents_double (battery->directory, "energy_now", &battery->energy_now, NULL, NULL);
if (battery->energy_now >= 0) {
......@@ -363,7 +364,6 @@ read_state(GbbPowerMonitor *monitor,
} else if (battery->charge_now >= 0) {
add_to (&state->charge_now, battery->charge_now);
add_to (&state->charge_full, battery->charge_full);
add_to (&state->voltage_now, battery->voltage_now);
if (battery->charge_full_design >= 0) {
if (n_batteries == 0 || state->charge_full_design >= 0)
......@@ -375,6 +375,12 @@ read_state(GbbPowerMonitor *monitor,
add_to (&state->capacity_now, battery->capacity_now);
}
/* state->voltage_now only makes sense if there is a single battery */
if (n_batteries == 0)
state->voltage_now = battery->voltage_now;
else
state->voltage_now = -1.0;
n_batteries += 1;
}
......