- 11 Jun, 2010 1 commit
-
-
David Zeuthen authored
Allow constructing a GDBusProxy for well-known names as discussed here http://mail.gnome.org/archives/gtk-devel-list/2009-October/msg00075.html including test cases. Make it possible to create a GDBusProxy for a GBusType instead of a GDBusConnection. This requires G_BUS_TYPE_NONE so add that too. Nuke g_bus_watch_proxy() since one can now more or less use GDBusProxy for this. Port gdbus-example-watch-proxy to this new API and include this example in the GDBusProxy doc page. Also nuke the GType parameter from the GDBusProxy constructors as requested here: https://bugzilla.gnome.org/show_bug.cgi?id=621229 Also update the porting guide and other API docs for this change. Also fix a bug in the signal dispatching code so each subscriber only get notified once, not N times, for the same signal. Also add a test case for this. https://bugzilla.gnome.org/show_bug.cgi?id=621213Signed-off-by:
David Zeuthen <davidz@redhat.com>
-
- 14 May, 2010 1 commit
-
-
Christian Persch authored
Use "&s" instead of "s", and free the variant iters after use. Bug #618663.
-
- 13 May, 2010 2 commits
-
-
David Zeuthen authored
After a long discussion, this has finally been standardized in the D-Bus spec. See http://lists.freedesktop.org/archives/dbus/2010-May/012667.html http://lists.freedesktop.org/archives/dbus/2010-May/012712.htmlSigned-off-by:
David Zeuthen <davidz@redhat.com>
-
David Zeuthen authored
This makes it possible to use the cached properties mechanism even if constructing the proxy with the DO_NOT_LOAD_PROPERTIES flag. This is useful for cases where you obtain the and track object properties out-of-band. For example, in udisks, the plan is to have something like this Manager.GetObjects (out ao paths, out aa{sa{sv}} all_properties); Manager.ObjectAdded (o path, a{sa{sv}} all_properties); Manager.ObjectChanged (o path, a{sa{sv}} all_properties); Manager.ObjectRemoved (o path, a{sa{sv}} all_properties); E.g. the first GetObjects() call will return *all* data about *all* exported objects. Further, this way a client will only need to listen these three signals (three AddMatch) on the Manager object and it will never need to do GetAll() etc (e.g. can use DO_NOT_LOAD_PROPERTIES). (Of course this only works if the client is interested in all objects... while this is true for udisks it is generally not true for other D-Bus services). Also use expected_interface to check for programming errors.
-
- 12 May, 2010 1 commit
-
-
David Zeuthen authored
-